Using ITCertKing you can pass the Nortel 920-159 exam easily. The first time you try to participate in Nortel 920-159 exam, selecting ITCertKing's Nortel 920-159 training tools and downloading Nortel 920-159 practice questions and answers will increase your confidence of passing the exam and will effectively help you pass the exam. Other online websites also provide training tools about Nortel certification 920-159 exam, but the quality of our products is very good. Our practice questions and answers have high accuracy. Our training materials have wide coverage of the content of the examination and constantly update and compile. ITCertKing can provide you with a very high accuracy of exam preparation. Selecting ITCertKing can save you a lot of time, so that you can get the Nortel 920-159 certification earlier to allow you to become a Nortel IT professionals.
In recent, ITCertKing began to provide you with the latest exam dumps about IT certification test, such as Nortel 920-159 certification dumps are developed based on the latest IT certification exam. ITCertKing Nortel 920-159 certification training dumps will tell you the latest news about the exam. The changes of the exam outline and those new questions that may appear are included in our dumps. So if you want to attend IT certification exam, you'd better make the best of ITCertKing questions and answers. Only in this way can you prepare well for the exam.
Exam Code: 920-159
Exam Name: Nortel (Ncss callpilot 2.x/3.0)
One year free update, No help, Full refund!
Total Q&A: 140 Questions and Answers
Last Update: 2014-01-29
ITCertKing is a website that can provide all information about different IT certification exam. ITCertKing can provide you with the best and latest exam resources. To choose ITCertKing you can feel at ease to prepare your Nortel 920-159 exam. Our training materials can guarantee you 100% to pass Nortel certification 920-159 exam, if not, we will give you a full refund and exam practice questions and answers will be updated quickly, but this is almost impossible to happen. ITCertKing can help you pass Nortel certification 920-159 exam and can also help you in the future about your work. Although there are many ways to help you achieve your purpose, selecting ITCertKing is your wisest choice. Having ITCertKing can make you spend shorter time less money and with greater confidence to pass the exam, and we also provide you with a free one-year after-sales service.
ITCertKing Nortel 920-159 practice test dumps are doubtless the best reference materials compared with other 920-159 exam related materials. If you still don't believe it, come on and experience it and then you will know what I was telling you was true. You can visit ITCertKing.com to download our free demo. There are two versions of ITCertKing dumps. The one is PDF version and another is SOFT version. You can experience it in advance. In this, you can check its quality for yourself.
ITCertKing ensure that the first time you take the exam will be able to pass the exam to obtain the exam certification. Because ITCertKing can provide to you the highest quality analog Nortel 920-159 Exam will take you into the exam step by step. ITCertKing guarantee that Nortel 920-159 exam questions and answers can help you to pass the exam successfully.
920-159 Free Demo Download: http://www.itcertking.com/920-159_exam.html
NO.1 Which three CallPilot features are supported by Business Communication Manager
(BCM) 3.0? (Choose three.)
A. ability to annotate faxes
B. ability to save voice messages
C. ability to reject passwords (such as 888888)
D. ability to set message sensitivity to urgent or Normal
Answer: A.B.D
NO.2 You are installing a CallPilot 3.0 system with 32 Voice channels, 8 Fax channels, and 4
ASR (automated speech recognition) Cannels using a CallPilot 702t server and a Meridian
1 IP Enable (IE) Option 61C switch. How many NTRB18CA MGate cards must be
installed in the switch to support this configuration?
A. 1
B. 2
C. 3
D. 4
Answer: B
Nortel 920-159 920-159 questions 920-159 920-159
NO.3 When installing a 96-chabbel 3.0 system using a 1003rp server and a CS 1000 system, how
would you install the Nortel Network software feature key adapter?
A. The Nortel Networks software feature Key adapter is installed in its bracket on the
motherboard in the 102rp server.
B. The Nortel Networks software feature Key adapter is installed in the COM1 serial port
connector on the rear of the 1002rp server.
C. The Nortel Networks software feature Key adapter is installed in the COM1 serial port
connector on the rear of the 1002rp server.
D. The Nortel Networks software feature Key adapter is installed in the Parallel port connector
LPT1 on the rear of the 1002rp server.
Answer: D
Nortel braindump 920-159 920-159 920-159 certification 920-159
NO.4 .When provisioning the Embedded Local Area Network (ELAN) on a CS 1000 system for a
site with a CallPilot 3.0 system with 96 DSO channels, what number should you set the
maximum number of call registers for CSL input (CSQI in LD 17)?
A. 20
B. 96
C. 192
D. 255
Answer: C
Nortel 920-159 certification 920-159 920-159
NO.5 .When installing a 40-channel CallPilot 3.0 system using a 201i server and a CS 1000
system, how do you connect the SCSI connection to the server?
A. The SCSI connection to the 201i server is made with the low profiles right-angle SCIS
connector on the SCIS connector on the 201i server faceplate.
B. NTRH3502SCSI cable attached to the SCSI connection to the 201i server is made with the
CD-ROM drive SCSI cable NTRH1408 attached from the SCIS connector on the 201i server
faceplate to the SCSI adapter A0763912 on the CD-ROM drive
C. NTRH3502SCSI cable attached to the SCSI connection to the 201i server is made via the
backplane connector in the Media Gateway or Media Gateway Expansion with the multi I/O
cable (NTRH0912) to the next drive in the SCIS chain.
D. NTRH3502SCSI cable attached to the SCSI connection to the 201i server is madewith the
intermediate SCIS cable NTRH1408 that connect from the SCIS connector on the 201i server
faceplate to the I/O panel connector and the NTRH410 SCSIcable that connect from the I/O
panel connector to the next device in the SCSI chain.
Answer: A
Nortel 920-159 920-159 study guide 920-159
NO.6 .Exhibit
Prior to installing a CallPilot 3.0 system, you review, the Configuration Wizard worksheet.
The customer has provided category 5 cable connections to their corporate LAN for the
Switch Ethernet connection, the CallPilot Server Customer LAN (CLAN) Ethernet
connection, and the CallPilot Server Embedded LAN (ELAN) Ethernet connection. The
network address information (shown in the exhibit) for the Switch IP address, the CallPilot
server ELAN IP address, and the CallPilot Server CLAN IP address integrate with the
customer's internal network. What action would you take?
A. Proceed with the installation using the category 5 cable connections, IP addresses and Subnet
mask provided by the customer.
B. Proceed with the installation but do not use the category 5 cable connections provided by the
customer for the Switch Ethernet connection and the CallPilot server ELAN Ethernet
connection. Use a separate category 5 cable that connects directly from the switch to the ELAN
network interface connector on the server.
C. Inform the customer that IP address beginning with 192.168 are private address and if used
the ELAN will not be able to be connected to the internet.
D. Inform the customer that the ELAN must be on a separate IP network isolated from the
CLAN. Recommend that they use a dedicated hub that can either be supplied by Nortel Network
or a third party for the ELAN and recommend different IP addresses for switch and the ELAN
NIC.
Answer: D
Nortel braindump 920-159 exam 920-159 920-159 certification training 920-159
NO.7 .XXXX .com has a CallPilot 3.0 configuration connected to a Meridian 1. the CallPilot
platform connect to the network loops in the IPE shelf through MGate cards. The MGate
cards plug into the Meridian 1 IPE shelf. Which three platform types connect using the
Mgate card? (Choose three.0?
A. 200i
B. 201i
C. 702t
D. 1001ro
E. 1002rp
Answer: A.B.C
NO.8 A site has a CallPilot server interworking with a Symposium server. Where are the
applications (announcement service, menus, etc.) stored to support Symposium to CallPilot
integration?
A. in a folder
B. in a mailbox
C. on the C drive
D. by a backup file
Answer: A
Nortel demo 920-159 920-159 920-159
NO.9 A site has a CallPilot 3.0 server. Which two administrative functions support the
web-based CallPilot Manager administrative application? (Choose two.)
A. Managing system configuration and backups
B. Creating application with Application Builder
C. Managing mailbox Users, groups, and permissions
D. Managing CallPilot Simple network Maintenance Protocol (SNMP) traps
Answer: A.C
NO.10 When installing a 40-channel 3.0 system using a 201i server and a Meridian 1 Option 11C
mini switch, how should you set the SCSI ID on the Tandberg SLR5 tape drive
(NTRH9038)?
A. Rotate the dial on the SCIS ID rotary switch unit the arrow points to 3.
B. Use the blade of a screwdriver to press either the plus (+) or minus (? Button the SCSI ID
switch to set the SCIS ID to 5.
C. Use the blade of a screwdriver to set DIP switches as follows.
1=ON, 2=off, 3=Off, 4=Off, 5=Off
D. The SCSI ID for the Tandberg SLR5 tape drive (NTRH9038) is set when you run the
Configuration Wizard after you install the CallPilot system.
Answer: B
Nortel 920-159 920-159 exam simulations 920-159 920-159
ITCertKing offer the latest 74-338 exam material and high-quality MB3-700 pdf questions & answers. Our NS0-504 VCE testing engine and 1Z0-466 study guide can help you pass the real exam. High-quality IIA-CIA-Part1 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.itcertking.com/920-159_exam.html